Section 7 – System Operational Testing
Page 51
Dukane Manual Part Number 403-572-03
System Verication Tests
Preliminary Setup
1. Plug in the AC line cord to the correct AC power
outlet. See Table 11 - I for the AC power require-
ments.
2. Attach a compatible ultrasonic probe to the system
output connector.
3. Push the AC Breaker/Switch A to the ON posi-
tion.
Testing a System
(Complete Steps 1-3 above, and then continue with
Steps 4 and 5 below.)
4. The INFO LED on the panel B should ash RED
for 5 10 seconds. Then, it turns off (GRAY), and
the LED above ONLINE C turns GREEN (if ON-
LINE).
5. ONLINE/OFFLINE Tests
a. Press the OFFLINE key.
The LED status indicator C turns to YELLOW.
b. Press the TEST key.
The ultrasound should not activate.
c. Press the ONLINE key.
The LED status indicator C will be GREEN.
d. Press and hold the TEST key. Ultrasound
should activate. The display shows amplitude,
power and operating frequency. The segmented
power bar graph should also appear.
See the sample screen display - Figure 7-2.
Release the TEST key.
Ultrasound should deactivate.
Figure 7-1 Control Panel at Start-up
Figure 7- 2 TEST Screen Display Sample
AMPLITUDE 100 %
POWER 1140 W
OPERATING FRQ 20000 Hz
0 20 40 60 80 100
B
C
A
AMPLITUDE 100%
POWER 0 W
FREE RUN FRQ 19899HZ