Section 4 – Standard Connections
Page 31
Dukane Manual Part Number 403-572-03
Figure 4- 6DB 25-F for Generator Output Connector
Figure 4 - 7DB-25M for Generator Output Cable
Connector
1 3 5 7 9 11 13
15 17 19
21 23 25
13 11 9 7 5 3 1
25 23 21 19 17 15
current loop input to the remote control option board is
connected and working normally. This output will be an
open circuit when the current loop input signal is too low
for proper system operation (less than 2mA). This may
be due to a broken wire connection, a failed current loop
controller or the current loop input wired incorrectly to
the input terminal block.
Pin 13 (Analog Monitor Signal Common)
Pin 13 is the signal common (ground) connection for all
of the analog monitor signals (on Pins 15 and 16). This
signal common pin is connected to system chassis ground
and is not isolated from the generator chassis. This is
an analog signal ground connection. Do not connect
anything to this ground connection, except the wiring to
the inputs of the analog instrumentation devices used to
measure the monitor output signals.
Pin 7 (Any Fault Status Output)
Pin 7 is a digital active low status output that activates
whenever any fault condition is detected that inhibits
ultrasound output and normal system operation. This
output will be an open circuit when no system fault
conditions are detected.
Generator faults that will activate the Any Fault output:
• Overload – Peak
• Overload – Average
• Overload – Frequency
• Overtemperature Fault
• System Power Fault
• Current Loop Fault
Pin 8 (Press Trigger Status Output)
NOT AVAILABLE
Pin 9 (System Overload Status Output)
Pin 9 is a digital active low status output that activates
whenever any overload condition is tripped. Activation
of the overload status output signal could be caused by
an average overload, a frequency overload or, a peak
overload condition. After the overload status output
activates, it will remain active until the next ultrasound
activation cycle begins and this output will automatically
reset. This output will be an open circuit when no
overload conditions have been detected.
Pin 10 (System On-Line Status Output)
Pin 10 is a digital active low status output that activates
when the system is in the ONLINE operating mode, which
enables the activation of the ultrasonic output. This output
will be an open circuit if the system is switched to the
OFFLINE operating mode, which will prevent the start
of a welding cycle or activation of the ultrasound output.
Note that an automation controlled process can not weld
any parts, if the system is, accidentally or otherwise,
switched to the OFFLINE operating mode.
Pin 11 (Press Top of Stroke Status Output)
NOT AVAILABLE
Pin 12 (Current Loop OK Status Output)
This status output signal will activate only when a
Remote Control Board is installed in the system. Pin 12 is
a digital active low status output that activates when the
NOTE
A Remote Control Board is also referred
to as a Remote Amplitude Control Board.
Continued