iQ Series, Ultrasonic Generator/Power Supply LS-E User’s Manual
Dukane Manual Part No. 403-588-00
Figure 4 - 6 DB-25F, Generator Output Connector (J3)
Pin 22 (System Ready Status Output)
This status output signal will activate only when the
system is ready to activate ultrasound or begin a weld
cycle. Pin 22 is a digital status output that activates
when a weld processing cycle is completed and the
welding process control system is ready to start the next
welding cycle. This output will be an open circuit when
the welding process controller determines that the next
welding cycle cannot be started. This includes system
faults or ofine active, but not a process fault like
Overload.
Pin 23 (Suspect Part Status Output)
Pin 23 is a digital status output that activates, either
momentarily or until the start of the next welding cycle,
when the welding parameters recorded during the
previous welding cycle are outside of the programmed
suspect part limits. This output will be an open circuit
after a welding cycle when a suspect part has not been
detected.
Pin 24 (Isolated Common)
Pin 24 is electrically isolated from chassis ground.
Pin 25 (Not Used)
Pin 25 is an open connection.
Figure 4 - 7 DB-25M, Generator Output Cable
Connector
1 3 5 7 9 11 13
15 17 19
21 23 25
13 11 9 7 5 3 1
25 23 21 19 17 15
Continued from Previous Page