iQ Series, Ultrasonic Generator/Power Supply LS-E User’s Manual
Dukane Manual Part No. 403-588-00
Pin Signal Name Connector
3 Setup Bit 0 Input
J2 (Page 24)
4 Setup Bit 1 Input
5 Setup Bit 2 Input
6 Setup Bit 3 Input
18 MPC Ready Out J3 (Page 29)
Table 11 - II MPC I/O Connector Signals
MPC I/O Connections
Signal names and Pin numbers and the connectors re-
lated to the MPC option are shown in the table below.
See the pages referred to in the table for more informa-
tion about the signals.
MPC Probe Control
When the optional MPC Interface and MPC I/O
connectors are used, the generator has the capability of
controlling as many as sixteen compatible probes. One
probe can be turned on at a time while the sequence of
probe activation is determined by the users automation.
The table below shows how the setup bit inputs
correspond to the probes.
MPC Probe
Selected
3 2 1 0
Off Off Off Off 1
Off Off Off On 2
Off Off On Off 3
Off Off On On 4
Off On Off Off 5
Off On Off On 6
Off On On Off 7
Off On On On 8
On Off Off Off 9
On Off Off On 10
On Off On Off 11
On Off On On 12
On On Off Off 13
On On Off On 14
On On On Off 15
On On On On 16
Table 11 - III MPC Setup Bit Inputs
NOTE
Ultrasound Output Connector
The ultrasound output connector
used with all standard generators is
a high voltage (5000V) coaxial style
SHV-BNC connector. This connector
provides superior shielding of electri-
cal noise, compared to other types
of connectors. The ultrasound output
connector mates with fully shielded
coaxial ultrasound cables that are
secured with a simple and reliable
quarter-turn bayonet style attachment
mechanism.
The ultrasonic output from this con-
nector (that drives the attached
ultrasonic load) is a very high AC
voltage. At high power levels this can
exceed 2 amps of current and must be
securely terminated via the ultrasound
cable for safe operation. Use original
equipment ultrasound cables for safe
and reliable system operation. Im-
properly assembled ultrasound cables
can result in high voltage arcing and
will destroy the ultrasound connectors.
Continued from Previous Page
Continued