iQ Series,Auto User’s Manual
Section 4 –System Operation
Page  29Page  28 
iQ Series,Auto User’s Manual
Section 4 –System Operation
Dukane Manual Part No. 403-573-02
Standard iQ Auto System
Operational Test
Step 1. Verify that the standard system installation is
complete and all cables are connected.
Refer to installation instructions included in Sec-
tion 3, if needed.
Refer to Section 6 - Automation Interface -for in-
formation on wiring system controls, if needed.
Step 2. After completing Step 1, activate line power to
the standard iQ Auto system.
Normal Condition:
GREEN - The POWER STATUS LED on the iQ
Auto panel should light up GREEN.
The system is now ready to operate.
Troubleshooting Abnormal iQ Auto System
Conditions
RED - If the POWER STATUS LED lights up
RED, check line voltage level.
GRAY - If the POWER STATUS LED is a
gray color (not lit), check line input.
Optional System Status Output to Monitor:
Optionally the Power OK status output can be
monitored on I/O connector Pin 6.
This NPN status output signal will activate when
power is OK.
Step 3. After completing Step 2, test ultrasound output
by activating I/O connector Pin 12.
Normal Condition:
The system is operating properly when power is
delivered to the attached stack.
Ultrasound Activation Connections:
Usually an automated control system is wired to
this control input.
Optionally - A manual switch could be wired to
this control input.
Figure 4-1 Generator POWER STATUS LED Detail
Options for U/S Activation Connections:
Optionally, monitor the U/S Active status output on
I/O connector Pin 4.
This NPN status output signal will activate when U/S
is ON.
Step 4. Other Options the Operator can Check:
Fault Status output signals
Fault Status output signals are available for:
Overload (Pin 3), or
Any Fault (Pin 5).
These NPN status outputs will activate when there is
a fault:
An Overload Fault latches until the next time U/S
is activated, or Fault Reset Input is activated..
Any Fault status activates when any fault is de-
tected by the system. It latches until the start of the
next cycle, or Fault Reset Input is activated.